skip to Main Content

North Goonyella Mine Fire 10th October 2018. “One of the in seam drainage blow skids was found to be breathing in. This indicates that the water trap underground has blown out and the gas could be free venting into the Mine atmosphere. Dennis Black stated that they would attempt to fill the riser and attempt to refill the water trap in this manner”

  • February 11, 2021

MRE - North Goonyella - 10.10.2018.pdf H9 temperature at 59 degrees C, drone with thermal indicator to be used as a check. This has gone up from the first reading…

North Goonyella Mine Fire MRE 29th September 2018. “the explosion vent doors on the H40 shaft had been displaced” “Dennis Black (VO) explained the current issues with the monitoring and how most of it was compromised by the current underground environment or else disconnected to prevent analyzer damage.”

  • February 7, 2021