skip to Main Content

North Goonyella Mine Fire 24th October Post A. “Mr Black stated results are unreliable due to lack of confirmed TB line integrity at 32G also uncertainties of integrity of a number of other TB lines. Mr Black explained the difficulties the Mine was experiencing with the tube bundle lines. When we asked about some of the results the Mr Black again stated that we could not rely on some of these gas readings.”

  • February 12, 2021

MRE - North Goonyella - 24.10.2018.pdf There are problems with the pressure readings, tube bundle lines and gas analysis results that the mine is collecting. Repairs to tube bundle lines.…

North Goonyella Mine Fire 10th October 2018. “One of the in seam drainage blow skids was found to be breathing in. This indicates that the water trap underground has blown out and the gas could be free venting into the Mine atmosphere. Dennis Black stated that they would attempt to fill the riser and attempt to refill the water trap in this manner”

  • February 11, 2021

MRE - North Goonyella - 10.10.2018.pdf H9 temperature at 59 degrees C, drone with thermal indicator to be used as a check. This has gone up from the first reading…